A technology enterprise integrating the R&D, manufacturing, sales, and application of ceramic fiber products (including equipment).
Technical Information
1. Thermal Conductivity Unit Conversion Table
| W/(m·K) | kcal/m·h·℃ | cal/cm·s·OF | B.T.U.in/ft2 ·h·F |
| 1 | 8.60000×10 4 | 2.3898×10 -5 | 1.76145×10 -1 |
| 1.16279 | 1 | 2.77800×10 -5 | 2.04820×10 -1 |
| 4.18571×10 4 | 3.60000×10 4 | 1 | 7.37290×10 -3 |
| 5.67715 | 4.88274 | 1.35630×10 -4 | 1 |
2. Empirical Formula for the Thermal Conductivity of Ceramic Fiber Products
1. Empirical formula for calculating the thermal conductivity of ceramic fiber blankets produced from natural raw materials:
λt = 0.035 + 0.203×(t average/1000)
2 kcal/m·h·℃
2. Empirical formula for calculating the thermal conductivity of ceramic fiber blankets manufactured from synthetic raw materials:
λt = 0.054 + 0.272×(t average/1000)
2 W/m·K